SensoNODE Gold Flow Sensors

SensoNODE Gold Flow Sensors

Flow constrictions in a compressed air system require higher operating pressures to overcome blockages.
Parker's flow sensor is able to report flow rate, differential pressure, and temperature. These data points
allow for monitoring of compressor outputs and system loops. These measurements enable users to see
the demand of their systems and identify inefficiencies in their operation. Detecting these inefficiencies
informs users to make proper decisions to reduce energy consumption and waste output.

Dimensions

RA68 25 FLRA68 40 FLRA68 50 FLRA68 63FLRR63 L1 FLRR63 L3 FL
ABABABABABAB
4.910.34.910.35.110.55.110.55.310.75.410.8
TRANSAIRRA68
25 FL
RA68
40 FL
RA68
50 FL
RA68
63 FL
RR63
L1 FL
RR63
L3 FL
TRANSAIR® PIPE DIAMETERS1"
(25MM)
1-1/2"
(40MM)
2"
(50MM)
2-1/2"
(63MM)
3"
(76MM)
4"
(101MM)
MEASUREMENT RANGE (SCFM)60 2003004006001,100
BASE MATERIALPOLYCARBONATE BRASS
WETTED MATERIALSTAINLESS STEEL 304
SEAL MATERIALNITRILE
PORTTRANSAIR® REDUCING BRACKET
PRESSURE RANGE0 TO 150 PSI (0 TO 10.3 BAR)
TEMPERATURE RANGE-4°F TO +167 °F (-20°C TO +75° C)
FULL RANGE LIFE CYCLES> 1 MILLION
CERTIFICATIONSFCC
BATTER (RECOMMENDED PANASONIC BRAND)CR123A
IP RATINGIP65

Sample Flow Trend Chart