SensoNODE Gold Flow Sensors
Flow constrictions in a compressed air system require higher operating pressures to overcome blockages.
Parker's flow sensor is able to report flow rate, differential pressure, and temperature. These data points
allow for monitoring of compressor outputs and system loops. These measurements enable users to see
the demand of their systems and identify inefficiencies in their operation. Detecting these inefficiencies
informs users to make proper decisions to reduce energy consumption and waste output.
Dimensions
RA68 25 FL | RA68 40 FL | RA68 50 FL | RA68 63FL | RR63 L1 FL | RR63 L3 FL | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
A | B | A | B | A | B | A | B | A | B | A | B |
4.9 | 10.3 | 4.9 | 10.3 | 5.1 | 10.5 | 5.1 | 10.5 | 5.3 | 10.7 | 5.4 | 10.8 |
TRANSAIR | RA68 25 FL | RA68 40 FL | RA68 50 FL | RA68 63 FL | RR63 L1 FL | RR63 L3 FL |
---|---|---|---|---|---|---|
TRANSAIR® PIPE DIAMETERS | 1" (25MM) | 1-1/2" (40MM) | 2" (50MM) | 2-1/2" (63MM) | 3" (76MM) | 4" (101MM) |
MEASUREMENT RANGE (SCFM) | 60 | 200 | 300 | 400 | 600 | 1,100 |
BASE MATERIAL | POLYCARBONATE BRASS | |||||
WETTED MATERIAL | STAINLESS STEEL 304 | |||||
SEAL MATERIAL | NITRILE | |||||
PORT | TRANSAIR® REDUCING BRACKET | |||||
PRESSURE RANGE | 0 TO 150 PSI (0 TO 10.3 BAR) | |||||
TEMPERATURE RANGE | -4°F TO +167 °F (-20°C TO +75° C) | |||||
FULL RANGE LIFE CYCLES | > 1 MILLION | |||||
CERTIFICATIONS | FCC | |||||
BATTER (RECOMMENDED PANASONIC BRAND) | CR123A | |||||
IP RATING | IP65 |